Key points for installation and application of electric control valves
Leave a message
Electric control valves are key implementation modules in the process of industrial automation. The products have stable performance, flexible application, and wide application fields. They are widely used in power engineering, chemical metallurgy, environmental protection, sewage treatment, light industry, and other industries.
Key points for installation and use of electric control valves:
For newly designed and installed control systems, to ensure that the control valve can work normally when driving and make the system run safely, before installing the new valve, you should first check whether the nameplate mark on the valve is consistent with the design requirements. At the same time, the following items should also be debugged. Basic error limit; full stroke deviation hysteresis; dead zone; leakage (in strict occasions). If the control valve in the original system is overhauled, in addition to verifying the above items, the sealing of the stuffing box and joints of the old valve should also be checked. In on-site use, many are often not caused by the quality of the control valve itself, but by improper installation and use of the regulating valve, such as improper installation environment, installation position and direction, or unclean pipelines.
Therefore, the following aspects should be noted when installing and using the electric control valve:
(1) The control valve is a field instrument, and the ambient temperature should be between 25 and 60 degrees Celsius, and the relative humidity should be less than 95%. If it is installed in an open-air or high-temperature environment, waterproofing and cooling measures should be taken. In places with vibration sources, it should be kept away from vibration sources or anti-vibration measures should be added.
(2) The control valve should generally be installed vertically and can be tilted in special circumstances. For example, when the tilt angle is large or the valve itself is too heavy, the valve should be protected by additional support parts.
(3) The pipeline where the control valve is installed should not be too high from the ground or floor. When the pipeline height is greater than 2 m, a platform should be set up as much as possible to facilitate the operation of the handwheel and maintenance.
(4) Before installing the control valve, the pipeline should be cleaned to remove dirt and welding slag. After installation, to ensure that no impurities remain in the valve body, the valve should be cleaned again, that is, all valves should be opened when the medium is passed to avoid impurities getting stuck. After using the handwheel mechanism, it should be restored to the original neutral position.
(5) To enable the production process to continue in the event of a failure or maintenance of the control valve, a bypass line should be added to the control valve. At the same time, special attention should be paid to whether the installation position of the control valve meets the requirements of the process.
(6) The electrical part of the electric control valve should be installed under the requirements of the relevant electrical equipment. If it is a flameproof product, it should be installed under the requirements of the "Electrical Equipment Installation Specifications in Explosion Hazardous Locations". If the on-site wire is SBH type or other six-core or eight-core, the outer diameter is about 11.3 mm. During use and maintenance, it is strictly forbidden to open the cover for maintenance and pry the flameproof surface in explosive locations. At the same time, do not damage or scratch the flameproof surface during disassembly and assembly, and restore it to the original flameproof requirement state after inspection and maintenance.
(7) After disassembly and repair of the reducer of the actuator, pay attention to lubrication. Low-speed motors are generally not disassembled, cleaned, and refueled. After assembly, check whether the valve position and valve position opening indication are consistent.